MATERIAL SAFETY DATA SHEET |
Company Name:
|
C.R. LAURENCE CO., INC.
|
Address:
|
2503 E. VERNON AVE.
|
City / State / Zip:
|
LOS ANGELES / CA / 90058
|
US-CHEMTREC Phone(I):
|
(800)424-9300
|
US-CHEMTREC Phone(II):
|
(703)527-3887
|
CAN-CANUTEC Phone:
|
(613)996-6666
|
Vendor Update:
|
9/11/2013
|
Date Prepared:
|
9/11/2013
|
MSDS Number:
|
RTV408AL
;
RTV408AL48GL
;
RTV408AL5GL
;
RTV408BGE
;
RTV408BGE48GL
;
RTV408BGE5GL
;
RTV408BL
;
RTV408BL48GL
;
RTV408BL5GL
;
RTV408BRZ
;
RTV408BRZ48GL
;
RTV408BRZ5GL
;
RTV408C
;
RTV408C48GL
;
RTV408C5GL
;
RTV408DT
;
RTV408T
;
RTV408T48GL
;
RTV408T5GL
;
RTV408W
;
RTV408W48GL
;
RTV408W5GL
;
|
|
|
I. CHEMICAL PRODUCT IDENTIFICATION
|
Product Name:
|
SILICONE SEALANT
|
HMIS Ratings:
|
|
NFPA Ratings:
|
|
|
Other:
|
THIS MATERIAL SAFETY DATA SHEET (MSDS) APPLIES TO THE FOLLOWING: RTV408C (CLEAR), RTV408BRZ (BRONZE), RTV408BL (BLACK), RTV408W (WHITE), RTV408AL (ALUMINUM), RTV408T (TAN), RTV408BGE (BEIGE).
|
|
II. COMPOSITION, INFORMATION ON INGREDIENTS
|
Chemical Ingredients |
C.A.S. Number |
% By Weight |
ACGIH TLV TWA/STEL |
OSHA PEL TWA/STEL |
Other TWA/STEL |
LD50 |
LC50 |
DIMETHYL SILOXANE HYDROXY-TERMINATED
|
70131-67-8
|
55.0-65.0
|
|
|
|
|
|
Notes |
|
POLYDIMETHYLSILOXANE, TRIMETHYL ENDCAP
|
63148-62-9
|
20.0-30.0
|
|
|
|
|
|
Notes |
|
SILICA, AMORPHOUS, FUMED
|
112945-52-5
|
5.0-10.0
|
10 MG/M3(TOTAL NUISANCE DUST)
|
15 MG/M3 (TOTAL NUISANCE DUST)
|
|
|
|
Notes |
|
METHYLOXIMINO SILANE
|
22984-54-9
|
1.0-5.0
|
|
|
|
|
|
Notes |
|
3-AMINOPROPYLTRIETHOXYSILANE
|
919-30-2
|
1.0-5.0
|
|
|
|
|
|
Notes |
|
VINYLOXIMINO SILANE
|
2224-33-1
|
1.0-5.0
|
|
|
|
|
|
Notes |
|
CARBON BLACK
|
1333-86-4
|
0.0-0.2
|
3.5 MG/M3
|
3.50 MG/M3
|
|
|
|
Notes |
|
.
|
|
|
|
|
|
|
|
Notes |
|
|
|
III. HAZARDS IDENTIFICATION PRIMARY ROUTE OF ENTRY
|
Eyes:
|
CAN CAUSE SEVERE IRRITATION.
|
Skin:
|
CAN CAUSE IRRITATION, POSSIBLE DERMAL SENSITIZATION. METHYL ETHYL KETOXIME MAY BE ABSORBED THROUGH THE SKIN.
|
Ingestion:
|
CAN CAUSE GASTROINTESTINAL IRRITATION.
|
Inhalation:
|
CAN CAUSE HEADACHE, DIZZINESS, NAUSEA, DROWSINESS, STUPOR, IRRITATION TO RESPIRATORY SYSTEM.
|
Signs and Symptoms of Exposure:
|
|
Other:
|
EMERGENCY OVERVIEW: VARIOUS COLORED PASTES. IF INHALED CAN CAUSE SEVERE IRRITATION TO RESPIRATORY SYSTEM. LEAVE AREA TO BREATHE FRESH AIR. AVOID FURTHER OVEREXPOSURE. IF SYMPTOMS PERSIST, GET MEDICAL ATTENTION IMMEDIATELY.
|
|
IV. FIRST AID MEASURES
|
Eyes:
|
IMMEDIATELY FLUSH WITH RUNNING WATER FOR 15 MINUTES, LIFTING THE UPPER AND LOWER LIDS OCCASIONALLY. GET MEDICAL ATTENTION IMMEDIATELY.
|
Skin:
|
WASH AREA OF CONTACT THOROUGHLY WITH HAND CLEANER FOLLOWED BY SOAP AND WATER. IF IRRITATION, RASH OR OTHER DISORDERS DEVELOP, GET MEDICAL ATTENTION IMMEDIATELY.
|
Ingestion:
|
GET MEDICAL ATTENTION IMMEDIATELY.
|
Inhalation:
|
LEAVE AREA TO BREATHE FRESH AIR. AVOID FURTHER OVEREXPOSURE. IF SYMPTOMS PERSIST, GET MEDICAL ATTENTION IMMEDIATELY.
|
|
V. FIRE FIGHTING MEASURES
|
Flash Point:
|
NOT APPLICABLE
|
Test Method:
|
TCC
|
Lower Flammability Limit:
|
N/A
|
Upper Flammability Limit:
|
N/A
|
Extinguishing Agents:
|
WATER FOG.
|
Unusual Fire or Explosion Hazards:
|
NOT APPLICABLE.
|
Fire Fighting Procedures:
|
DURING A FIRE, PERSONNEL AT THE SCENE ARE TO PREVENT EXPOSURE TO FUMES USING ACCEPTED FIRE FIGHTING TECHNIQUES.
|
Other:
|
OTHER PRECAUCTIONS: NOT APPLICABLE.
|
|
VI. ACCIDENTAL RELEASE MEASURES
|
Containment/Cleanup:
|
ABSORB SPILL IN SAND, EARTH OR OTHER SUITABLE MATERIAL. TRANSFER TO APPROPRIATE CONTAINER FOR DISPOSAL.
|
|
VII. HANDLING AND STORAGE
|
Other:
|
STORE UNDER NORMAL WAREHOUSE CONDITIONS. PREVENT INHALATION OF VAPOR, INGESTION, AND CONTACT WITH SKIN AND EYES. KEEP CONTAINER CLOSED WHEN NOT IN USE. PRECAUTIONS ALSO APPLY TO EMPTIED CONTAINERS. CHANGE SOILED WORKCLOTHES FREQUENTLY. CLEAN HANDS THOROUGHLY AFTER HANDLING. PERSONAL PROTECTIVE EQUIPMENT MUST BE WORN DURING MAINTENANCE OR REPAIR OF CONTAMINATED MIXER, REACTOR, OR OTHER EQUIPMENT.
|
|
VIII. EXPOSURE CONTROLS/PERSONAL PROTECTION
|
Eyes:
|
WEAR SUITABLE SAFETY EYEWEAR.
|
Skin:
|
PROTECT HANDS WITH IMPERVIOUS RUBBER GLOVES AND WEAR TYPICAL FULL COVER CLOTHING. PREVENT CONTACT WITH SKIN. FACE: NOT REQUIRED.
|
Respiratory:
|
WEAR APPROPRIATE, PROPERLY FITTED NIOSH/OSHA APPROVED RESPIRATOR AS DIRECTED BY THE MANUFACTURER WHEN THE VENTILATION IS NOT ADEQUATE.
|
Engineering:
|
USE LOCAL EXHAUST WHEN THE GENERAL VENTILATION IS NOT ADEQUATE.
|
|
IX. PHYSICAL AND CHEMICAL PROPERTIES
|
Appearance:
|
VARIOUS COLORED PASTE
|
Boiling Point:
|
N/A
|
Freezing Point:
|
N/A
|
pH:
|
N/A
|
Solubility in Water:
|
NEGLIGIBLE
|
Specific Gravity:
|
1.002
|
Vapor Pressure:
|
N/A
|
Vapor Density:
|
N/A
|
Physical State:
|
PASTE
|
Volatile Content:
|
VOC COMPLIANT, LESS THAN 39 g/L. VOLATILE WEIGHT: 3.5%.
|
|
X. STABILITY AND REACTIVITY
|
Stability:
|
STABLE.
|
Hazardous Polymerization:
|
HAZARDOUS POLYMERIZATION WILL NOT OCCUR.
|
Incompatible Products:
|
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
|
|
XI. TOXICOLOGICAL INFORMATION
|
Other:
|
SEE SECTION III.
|
|
XII. ECOLOGICAL INFORMATION
|
Environmental Fate and Distribution:
|
N/A
|
|
XIII. DISPOSAL CONSIDERATIONS
|
Disposal Method:
|
NOT REGULATED BY RCRA. DISPOSE OF IN COMPLIANCE WITH STATE AND LOCAL REGULATIONS.
|
RCRA Class:
|
N/A
|
Other:
|
EPA REPORTABLE QUANTITIES: N/A
|
|
XIV. TRANSPORT INFORMATION
|
D.O.T. Shipping Name:
|
NOT REGULATED
|
|
XV. REGULATORY INFORMATION
|
TSCA Status:
|
ON THE TSCA INVENTORY.
|
EPA Sara Title III Chemical Listings:
|
SARA 311 RATINGS: IMMEDIALTE HEALTH HAZARD - Y; DELAYED HEALTH HAZARD - Y; FIRE HAZARD: N; REACTIVITY HAZARD: N; SUDDEN RELEASE OF PRESSURE HAZARD: N. NO SARA 313 INGREDIENTS.
|
California:
|
NO PROPOSITION 65 INGREDIENTS.
|
Other:
|
OSHA STATUS: CONSIDERED HAZARDOUS BASED ON THE FOLLOWING CRITERIA: IRRITANT, SENSITIZER. TARGET ORGANS: LUNG, SKIN, EYE, KIDNEY. OSHA HAZARDOUS COMPONENTS: SILICA, AMORPHOUS, FUMED 112945-52-5; CARBON BLACK 1333-86-4, LISTED AS AN IARC, NTP, OSHA, OR ACGIH CARCINOGEN. NO COMPLIANCE QUANTITIES.
|
|
XVI. OTHER INFORMATION
|
Other:
|
FOR INDUSTRIAL USE ONLY. KEEP OUT OF REACH OF CHILDREN.
|
|
WARRANTY INFORMATION
|
THIS INFORMATION IS OFFERED IN GOOD FAITH AS TYPICAL VALUES AND NOT AS A PRODUCT SPECIFICATION. NO WARRANTY, EXPRESSED OR IMPLIED, IS HEREBY MADE. THE RECOMMENDED INDUSTRIAL HYGIENE AND SAFE HANDLING PROCEDURES ARE BELIEVED TO BE GENERALLY APPLICABLE. HOWEVER, EACH USER SHOULD REVIEW THESE RECOMMENDATIONS IN THE SPECIFIC CONTEXT OF THE INTENDED USE AND DETERMINE WHETHER THEY ARE APPROPRIATE.
|